Inverter Module
w12k400R
- 12,5 kW HF Converter
- Frequency Range: 20 kHz – 400 kHz
- 12,5 kW in 0,9 litres
- Power Density: 14 kW/litre
- Efficiency: 98,2% @ 400 kHz
- Efficiency: 98,9% @ 20 kHz
- Weight: 1,5 kg
APLICATIONS
- Induction Bonding
- Induction Brazing
- Induction Annealing
- Stress Relieving
- Induction Hardening
GENERAL FEATURES | |
---|---|
Output Power | 12,5 kW |
Output Frequency Range | 20…400 kHz |
Single-Power Port | 1 x 12,5 kW |
Efficiency | 98.9% @ 20 kHz / 98,2% @ 400 kHz |
Power Density | 14 kW/litre |
Power Specific Weight | 8,3 kW/kg |
INPUT | |
Mains Voltage (3) | 400 VAC |
Normal Operating Range (3) | 400 VAC ± 10 % |
Input AC Current (400 kHz) | 21,4 AAC @ 360 VAC, 17,5 AAC @ 440 VAC |
Input AC Power (400 VAC) | 13,2 kVA @ 20 kHz / 13,3 kVA @ 400 kHz |
Normal Operating Frequency Range | 47,5 / 63 Hz |
Cos (φ) | > 0,99 |
OUTPUT | |
Output Circuits | Series LC |
Inductor Short Circuit Protection | Yes |
CONTROLLER | |
Controller | Fully Digital Controller |
Control Strategies | FM |
Power Regulation Range (1) | 5…100% |
Current Regulation Range(1) | 5…100% |
Power Setting Time(2) | < 50 ms |
MECHANICAL SPECIFICATIONS | |
Size (width x depth x height) | 140 x 187 x 33 mm |
Weight | 1,5 kg |
COOLING SPECIFICATIONS | |
Cooling | Water |
Water Maximum Temperature | 40°C |
Minimum Water | 5 l/min |
ENVIRONMENTAL CONDITIONS | |
Environmental Temperature Range | -10°C to +40°C |
Maximum Humidity | 0.9 |
COMMUNICATION | |
Interfaces | CAN BUS (transparent) Interface |
NOTE:
(1) At Nominal Load
(2) At Adaptive Mode
(3) For 480 VAC contact us
Subject to changes
Need further infomation?
Our team is looking forward to hear about you. We are willing to know your needs in order to help you in every aspect related to induction.
Do not hesitate to contact us.