逆变器模块
w50k400R
- 50 kW HF Converter
- Frequency Range: 20 kHz – 400 kHz
- 50 kW in 9,8 litres
- Power Density: 5 kW/litre
- Efficiency: 98,2% @ 400 kHz
- Efficiency: 98,9% @ 20 kHz
- Weight: 10 kg
APLICATIONS
- Induction Bonding
- Induction Brazing
- Induction Annealing
- Stress Relieving
- Induction Hardening
| GENERAL FEATURES | |
|---|---|
| Output Power | 50 kW |
| Output Frequency Range | 20...400 kHz |
| Single-Power Port | 1 x 50 kW |
| Efficiency | 98,9% @ 20 kHz / 98,2% @ 400 kHz |
| Power Density | 5 kW/litre |
| Power Specific Weight | 5 kW/kg |
| INPUT | |
| Mains Voltage (3) | 400 VAC |
| Normal Operating Range (3) | 400 VAC ± 10 % |
| Input AC Current (400 kHz) | 85,5 AAC @ 360 VAC, 70 AAC @ 440 VAC |
| Input AC Power (400 VAC) | 52,9 kVA @ 20 kHz / 53,3 kVA @ 400 kHz |
| Normal Operating Frequency Range | 47,5 / 63 Hz |
| Cos (φ) | > 0,99 |
| OUTPUT | |
| Output Circuits | Series LC |
| Inductor Short Circuit Protection | Yes |
| CONTROLLER | |
| Controller | Fully Digital Controller |
| Control Strategies | FM |
| Power Regulation Range | (1) 5...100% |
| Current Regulation Range | (1) 5...100% |
| Power Setting Time | (2) < 50 ms |
| MECHANICAL SPECIFICATIONS | |
| Size (width x depth x height) | 300 x 310 x 105 mm |
| Weight | 10 kg |
| COOLING SPECIFICATIONS | |
| Cooling | Water |
| Water Maximum Temperature | 40°C |
| Minimum Water Flow | 5 l/min |
| ENVIRONMENTAL CONDITIONS | |
| Environmental Temperature Range | -10°C to +40°C |
| Maximum Humidity | 90% |
| COMMUNICATION | |
| Interfaces | CAN BUS (transparent) Interface |
NOTE:
(1) At Nominal Load
(2) At Adaptive Mode
(3) For 480 VAC contact us
Subject to changes