Converter Module i50k400R

Download the brochure in PDF (rev.2020-04-02)

GENERAL FEATURES
Output Power 50 kW
Output Frequency Range 10…400 kHz
Multi-Power Port 4 x 12,5 kW Independent Power Ports
Efficiency 98,9% @ 20 kHz / 98,2% @ 400 kHz
Power Density 21 kW/litre
Power Specific Weight 15 kW/kg
INPUT
Mains Voltage 400 VAC (Three-Phase)
Normal Operating Range 400 VAC ± 10 %
Input AC Current (400 kHz) 85,5 AAC @ 360 VAC, 70 AAC @ 440 VAC
Input AC Power (400 VAC) 52,9 kVA @ 20 kHz / 53,3 kVA @ 400 kHz
Normal Operating Frequency Range 47,5 / 63 Hz
Cos (φ) > 0,99
OUTPUT
Output Circuits Series LC
Inductor Short Circuit Protection Yes
CONTROLLER
Controller Fully Digital Controller
Control Strategies FM
Power Regulation Range (1) 5…100%
Current Regulation Range(1) 5…100%
Power Setting Time(2) < 50 ms
MECHANICAL SPECIFICATIONS
Size (width x depth x height) 257 x 293 x 33 mm
Weight 3,5 kg
COOLING SPECIFICATIONS
Cooling Water cooling
Water Maximum Temperature 40°C
Minimum Water Flow 5 l/min
ENVIRONMENTAL CONDITIONS
Environmental Temperature Range -10°C to +40°C
Maximum Humidity 90%
COMMUNICATION
Interfaces CAN BUS (basic) Interface

(1) At Nominal Load
(2) At Adaptative Mode